Test Code LAB3001 Miscellaneous Body Fluid Culture with Gram Stain
Additional Codes
NOTE: This test is used for body fluids whose sources do not fall into any of the following specimen types. If specimen source is one of the following, please utilize its corresponding test code.
-LAB3001A - Pleural Fluid Culture Panel
-LAB3001B - Peritoneal Fluid Culture Panel
-LAB3001C - Synovial Fluid Culture Panel
-LAB3001D - Pericardial Fluid Culture Panel
Intended Use
To isolate and identify pathologically significant organisms from normally sterile body fluids.
Methodology
Conventional Culture Technique/Conventional Gram Stain Procedure
Performing Laboratory
RCH-SPH
Specimen Requirements
Specimen Type:
Body Fluid
Container Type:
Preferred: Screw-capped Sterile Container (1 mL Minimum)
Acceptable: Isolater tube or Culture Swabs/Eswabs (If less than 1 mL)
Specimen Stability
For internal specimens:
Ambient: Forward to lab promptly, maintain sterility.
For outside sites sending specimen to RCH:
Refrigerated: Forward promptly, maintain sterility.
Day(s) Test Set Up
Monday through Sunday
Test Classification and CPT Coding
87205 - gram stain
87070 - aerobic culture
87075 - anaerobic culture