Test Code LAB472 Hepatitis B Surface Antibody

Intended Use

Used to aid in the diagnosis of hepatitis B virus in unvaccinated patients and to determine the immune status of vaccinated patients. Anti-HBs generally remains detectable in a HBV-exposed individual indefinitely, engendering immunity to future infections with HBV. However, in some patients, anti-HBs can decrease below detectable thresholds, but this does not necessarily correlate with loss of immunity to HBV as levels may quickly reach a detectable threshold following HBV re-exposure. During this period of undetectable anti-HBs, Anti-HBc (total) may be the only detectable serological marker for HBV infection.

Methodology

Chemiluminescence Immunoassay

Performing Laboratory

RCH

Specimen Requirements

Preferred: Serum

Container/Tube: Plain, red-top or gold, gel tube

Acceptable: Plasma

Container/Tube:  Lt Green/Mint top (lithium heparin) tube

Specimen:  1.0 mL (minimum volume 0.1 mL) 

Collection Instructions:  Forward promptly. 

Specimen Stability

Ambient: 1 day
Refrigerated: 7 days
Frozen (-20ºC): Up to 6 freeze/thaw cycles

Day(s) Test Set Up

Monday through Sunday

Test Classification and CPT Coding

86706