Sign in →

Test Code LAB535 Vitamin D 25-Hydroxy

Intended Use

Quantitative determination of total 25-hydroxyvitamin D levels in human serum to aid in the assessment of vitamin D sufficiency

Methodology

Enzyme Immunoassay (EIA)

Performing Laboratory

RCH-SPH

Specimen Requirements

Preferred: Plasma (heparinized)

Container/Tube:  Lt Green/Mint top (lithium heparin) tube

 

Acceptable: Serum

Container/Tube:  Plain, red-top or gold, serum gel tube

 

Specimen:  1.0 mL (minimum volume 0.55 mL)

 

Collection Instructions: Forward promptly, Avoid grossly lipemic or hemolyzed samples. 

Specimen Stability

Refrigerated (preferred): 7 days

Ambient: 8 hours

Frozen (< -20C): 1 year, no more than 3 thaw cycles

Day(s) Test Set Up

Monday through Sunday

Test Classification and CPT Coding

82306