Test Code MSH2 MSH2 Immunostain, Technical Component Only
Ordering Guidance
This test includes only technical performance of the stain (no pathologist interpretation is performed).
For immunostain detection of MLH1 protein without interpretation, order MLH1 / MLH1 Immunostain, Technical Component Only.
For immunostain detection of MSH6 protein without interpretation, order MSH6 / MSH6 Immunostain, Technical Component Only.
For immunostain detection of PMS2 protein without interpretation, order PMS2 / PMS2 Immunostain, Technical Component Only.
For immuno stain detection of MLH1, MSH2, MSH6, and PMS2 for miscellaneous tumors without interpretation, order IHC / Mismatch Repair (MMR) Protein Immunohistochemistry Only, Tumor.
For interpretation and diagnosis of submitted pathology specimens with appropriate additional stains and other ancillary testing, order PATHC / Pathology Consultation.
Additional material may be needed if alternative testing is requested. See the specific specimen requirements for the alternative requested testing.
Shipping Instructions
Attach the green "Attention Pathology" address label (T498) and the pink Immunostain Technical Only label included in the kit to the outside of the transport container.
Necessary Information
If sending both normal and tumor blocks; indicate the block number to be stained in performing lab notes (electronic orders) or on the enclosed paperwork (manual orders).
Specimen Required
Specimen Type: Tissue
Supplies: Immunostain Technical Only Envelope (T693)
Container/Tube: Immunostain Technical Only Envelope
Submit:
-Formalin-fixed, paraffin-embedded tissue block
OR
-2 Unstained, positively charged glass slides (25- x 75- x 1-mm) per test ordered; sections 4-microns thick
Useful For
Identifying patients at high risk for having hereditary nonpolyposis colorectal cancer, also known as Lynch syndrome, in an immunopanel including MSH2 and other mismatch repair markers
Evaluation of tumor tissue to identify patients at risk for having hereditary endometrial carcinoma in an immunopanel including MSH2 and other mismatch repair markers
Method Name
Immunohistochemistry (IHC)
Reporting Name
MSH2 IHC, Tech OnlySpecimen Type
TECHONLYSpecimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
TECHONLY | Ambient (preferred) | |
Refrigerated |
Day(s) Performed
Monday through Friday
Report Available
1 to 3 daysPerforming Laboratory

Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
88342-TC, Primary
88341-TC, If additional IHC
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
MSH2 | MSH2 IHC, Tech Only | Order only;no result |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
70824 | MSH2 IHC, Tech Only | Bill only; no result |
Forms
If not ordering electronically, complete, print, and send a Immunohistochemical (IHC)/In Situ Hybridization (ISH) Stains Request (T763) with the specimen.