Test Code LAB494 Rapid Plasma Reagin (RPR), Serum
Intended Use
Used to aid in the diagnosis of syphilis. Note: This test is used only in the event of a reactive syphilis antibody test or in patients with a history of a reactive RPR. This will also reflex a titer if indicated.
Methodology
Multiplex Immunoassay
Performing Laboratory
RCH
Specimen Requirements
Preferred: Serum
Container/Tube: Plain red-top or serum gel tube
Acceptable: Plasma (heparinized)
Container/Tube: Lt Green/Mint top tube
Specimen: 1.0 mL (minimum volume 0.3 mL)
Collection Instructions: Forward promptly.
Specimen Stability
Refrigerated: 7 days
Frozen: -20C > 5 days
Day(s) Test Set Up
Monday through Sunday
Test Classification and CPT Coding
86292, titer (if indicated) 86593